Theory Flow Sensors

Flow sensors measure the flow rate of a gas or liquid. This makes them indispensable in many technological applications. There are different methods to measure the flow.

34 Products found

PFLOWC5001

Measuring range [SCCM]
0 to 0.05...20 SLPM
Output signal
Linear, 0.5...4.5 VDC, RS232, Rs485 Modbus
Accuracy [± % FS] max.
±1 r.d. or ±0.2 f.s whichever is larger
Supply voltage [VDC]
8...24

PFLOW5001

Measuring range [SCCM]
0 to 0.1...20 SLPM or 0 to ±0.1...±20 SLPM
Output signal
Linear, 0.5...4.5 VDC, Rs485 Modbus, I2C
Accuracy [± % FS] max.
±1 r.d. or ±0.2 f.s whichever is larger
Supply voltage [VDC]
8...24

PFLOW5002 / PFLOWC5002

Measuring range [SCCM]
0 to 0.05...20 SLPM
Output signal
Linear, 0.5...4.5 VDC, RS232, Rs485 Modbus
Accuracy [± % FS] max.
±1 r.d. or ±0.2 f.s whichever is larger
Supply voltage [VDC]
8...24

PFLOW3000

Measuring range [SCCM]
0 to 2...50 SLPM
Output signal
Linear, 0.5...4.5 VDC, Rs485 Modbus, I2C
Accuracy [± % FS] max.
±(1.5+0.2FS)
Supply voltage [VDC]
8...24

PFLOW4008

Measuring range [SCCM]
0 to 2...50 SLPM
Output signal
Linear, 0.5...4.5 VDC, IO-Link, I2C
Accuracy [± % FS] max.
1.5
Supply voltage [VDC]
8...24

PFLOW2001

Measuring range [SCCM]
0 to 10...5000 SCCM
Output signal
Linear, 0.5...4.5 VDC, I2C
Accuracy [± % FS] max.
1.5
Supply voltage [VDC]
2.7...15
New

PFLOW9015CL

Measuring range [SCCM]
0..100 SLPM
Output signal
I2C
Accuracy [± % FS] max.
±2%
Supply voltage [VDC]
5V ±5%

PFLOW-CUSTOM-MADE

Measuring range [SCCM]
Customized
Output signal
Customized
Accuracy [± % FS] max.
Customized
Supply voltage [VDC]
Customized

V3D air velocity sensor

Measuring range [SCCM]
0 to 30...4000 SCCM
Output signal
Linear, 0.5...4.5 VDC
Accuracy [± % FS] max.
5
Supply voltage [VDC]
2.75...5.5

PFLOW-ELEMENT

Measuring range [SCCM]
Customized
Output signal
Customized
Accuracy [± % FS] max.
Customized
Supply voltage [VDC]
Customized

PFLOW10U-2210

Measuring range [SCCM]
0...10
Output signal
Linear, 1...5 VDC
Accuracy [± % FS] max.
2.5
Supply voltage [VDC]
8...14

PFLOW301U-2210

Measuring range [SCCM]
0...30
Output signal
Linear, 1...5 VDC
Accuracy [± % FS] max.
2.5
Supply voltage [VDC]
8...14

PFLOW202U-2210

Measuring range [SCCM]
0...200
Output signal
Linear, 1...5 VDC
Accuracy [± % FS] max.
2
Supply voltage [VDC]
8...14

PFLOW113U-2210

Measuring range [SCCM]
0...1000
Output signal
Linear, 1...5 VDC
Accuracy [± % FS] max.
2
Supply voltage [VDC]
8...14

PFLOW213U-2210

Measuring range [SCCM]
0...2000
Output signal
Linear, 1...5 VDC
Accuracy [± % FS] max.
2
Supply voltage [VDC]
8...14

SQ-UST_L_0001-01

Operating medium
Flüssigkeit
Contact area
Stahl
Temperature range
+90°C

SQ-UST_L_0002-01

Operating medium
Flüssigkeit
Contact area
Messing
Temperature range
+130°C

SQ-UST_L_0003-01

Operating medium
Flüssigkeit
Contact area
Kunststoff
Temperature range
+55°C

SQ-UST_L_0103-01

Operating medium
Flüssigkeit
Contact area
Stahl
Temperature range
+75°C

SQ-UST_L_0104-01

Operating medium
Flüssigkeit
Contact area
Stahl
Temperature range
+75°C